湿式氧化法脱硫在生产中经常出现堵塔的现象

首页- 新闻资讯 > 行业资讯 > 2022-05-16

湿式氧化法脱硫在生产中经常出现堵塔的现象。

Tower blockage often occurs in wet oxidation desulfurization.
可以说自湿式氧化法脱硫在生产中应用以来,堵塔现象一直伴随其中,虽然随着科学技术的快速发展,许多新型脱硫催化剂已经具备清塔洗堵的能力,使堵塔现象得以缓和,但由于企业的工况、操作和管理等原因,使堵塔现象仍然是行业脱硫目前普遍关注的焦点。多年来我们经过走访、调研并加以总结找出其形成的原因,主要有以下几个方面:
It can be said that the tower blocking phenomenon has been accompanied since the application of wet oxidation desulfurization in production. Although with the rapid development of science and technology, many new desulfurization catalysts have the ability to clean and clean the tower blocking, which can alleviate the tower blocking phenomenon, the tower blocking phenomenon is still the focus of general attention in the desulfurization industry due to the working conditions, operation and management of enterprises. Over the years, we have visited, investigated and summarized to find out the reasons for its formation, mainly in the following aspects:
1、进脱硫塔的气体成分不好,杂质含量较多(如粉煤灰、煤焦油及其它固体颗粒等)。这种现象主要是前工段水洗塔及静电除焦运行不正常造成的。
1. The gas entering the desulfurization tower has poor composition and high impurity content (such as fly ash, coal tar and other solid particles). This phenomenon is mainly caused by the abnormal operation of the water washing tower and electrostatic coke removal in the front section.
2.填料塔在脱硫反应过程时,同时也伴随着氧化析硫过程,析出的硫过多(特别是入口H2S含量较高时),不能及时随脱硫液带出脱硫塔,会在填料表面粘结,导致出现局部堵塞,偏流,严重时形成堵塔。
2. The desulfurization reaction process of the packed tower is also accompanied by the oxidation sulfur precipitation process. Too much sulfur is precipitated (especially when the inlet H2S content is high) and cannot be brought out of the desulfurization tower with the desulfurization liquid in time, which will bond on the surface of the packing, resulting in local blockage, bias flow and blocking tower in serious cases.
3、脱硫塔喷淋密度不够。一般要求在35-50m3/m2.h。较低的喷淋密度不仅会使塔内填料形成干区造成硫堵而且会大大降低脱硫塔的净化度。特别对于直径较大的塔一定要保证足够的贫液量,当遇到减机减量或入口H2S较低时,切不可盲目降低循环量。此时为了降低消耗可采取降低溶液组分的办法来达到目的。
3. The spray density of desulfurization tower is not enough. The general requirement is 35-50m3 / m2 h。 The lower spray density will not only form a dry area of the packing in the tower, resulting in sulfur blockage, but also greatly reduce the purification degree of the desulfurization tower. Especially for the tower with large diameter, sufficient lean liquid volume must be ensured. When the unit is reduced or the inlet H2S is low, the circulation volume must not be reduced blindly. At this time, in order to reduce consumption, the method of reducing solution components can be adopted to achieve the purpose.
4、空气量不够(一般要求在60-100m3/m2.h),或设备不配套。这种现象必然造成槽内硫泡沫浮选困难,使贫液中悬浮硫较高,若长时间运行很容易形成塔堵。
4. The air volume is insufficient (generally 60-100m3 / m2. H), or the equipment is not matched. This phenomenon will inevitably lead to difficulties in sulfur foam flotation in the tank, resulting in high suspended sulfur in the lean solution. If it is operated for a long time, it is easy to form tower blockage.
5、脱硫塔的设备结构本身有问题,如填料选择不当或塔的液体分布器、再布器结构或安装不合理。这种现象很容易使溶液偏流或分布槽本身积硫而造成塔堵。
5. There are problems in the equipment structure of the desulfurization tower, such as improper selection of filler or unreasonable structure or installation of liquid distributor and redistributor of the tower. This phenomenon is easy to make the solution bias flow or sulfur accumulation in the distribution tank itself, resulting in tower blockage.
本文的精彩内容由湿法脱硫提供知识提供,本网站还有很多的精彩内容,更多的内容您可以点击进入:我们有专门的客服为您解答问题
The wonderful content of this article is provided by the knowledge of wet desulfurization. There are many wonderful contents on this website. You can click to enter more contents: We have special customer service to answer your questions